500kV, 168kV, 71.5kV, 167MVA Power Transformer

Standard

IEC 60076, IEC 60214, IEC 60071, IEC 60529, IEEE C57, ANSI, ISO 9001:2015,  ISO 14001:2015, ISO 45001:2018, ISO/IEC 17025

Warranty

24 months after commissioning

Lead Time

14 months

TESTING

Routine Tests

  • Visual and dimensional inspection
  • Winding resistance measurement
  • Transformer Turns Ratio (TTR) verification
  • Vector group and polarity verification
  • No-load loss and excitation current measurement
  • Load loss and short-circuit impedance test
  • Applied AC withstand voltage test
  • Induced AC overvoltage withstand test
  • Insulation resistance measurement
  • Oil dielectric strength and moisture analysis
  • OLTC operational and functional testing
  • Leak test and pressure integrity verification
  • Bushing electrical testing
  • Current Transformer (CT) verification
  • Final mechanical inspection and documentation review

Type and Special Tests (as specified)

  • Lightning Impulse Withstand Test (LI)
  • Switching Impulse Test (SI)
  • Temperature Rise Test
  • Partial Discharge Measurement
  • Sound Level Measurement
  • Short-Circuit Withstand Verification
  • Zero-Sequence Impedance Test
  • Dissolved Gas Analysis (DGA)
  • Customer Witness Factory Acceptance Test (FAT)
Product Features
  • Three-winding Extra High Voltage (EHV) transformer designed for 500 kV transmission networks.
  • Rated 167 MVA continuous duty with excellent overload capability.
  • High-efficiency grain-oriented silicon steel core minimizing no-load losses and noise.
  • Robust copper windings with superior mechanical strength for short-circuit withstand.
  • Advanced oil-directed cooling system for reliable thermal performance.
  • Precision On-Load Tap Changer (OLTC) for accurate voltage regulation.
  • Low partial discharge insulation system for enhanced long-term reliability.
  • High dielectric strength insulation designed for demanding EHV applications.
  • Heavy-duty welded steel tank with corrosion-resistant coating suitable for tropical and coastal environments.
  • Conservator system with diaphragm or air-cell to maintain oil quality.
  • Stainless steel piping and radiators for long service life.
  • Integrated online monitoring options including:
  • Dissolved Gas Analysis (DGA)
  • Fiber-optic winding temperature monitoring
  • Top oil temperature indicator
  • Moisture-in-oil monitoring
  • Bushing condition monitoring
  • Online OLTC monitoring
  • Engineered for a design service life exceeding 40 years under normal operating conditions.
  • Fully customizable to meet utility, transmission, and large-scale infrastructure project specifications.
  •